Model | AXH19W |
Compliance | ATEX | ATEX certificate no. Presafe 18 ATEX 13084X |
IECEx certificate no. IECEx PRE 18.0054X |
CE2776 | ExII 2 G Ex db IIC T6 Gb – Suitable for Gas Zone 1 & 2 |
ExII 2 D Ex tb IIIC T80°C Db – Suitable for Dust Zone 21 & 22 |
Ingress Protection | IP 68 (1.2 m, 45 mins) |
Dimensions | External | 524 (L) x 208 (H) x 179 (W) mm |
Internal | 364 (L) x Ø132mm |
Internal Camera space | 250 (L) x 80 (H) x 80 (W) mm (Max camera + lens size) |
Mechanical | Construction | Stainless Steel 316L |
Finishing | Polished |
Window | Tempered Glass |
Window Glass Thickness | 12mm |
Window Glass Diameter | 70mm |
No. of Cable Entries | 2 |
Cable Entry Size/ Thread | M25/1.5 |
Max. Cable Pass through Size | 15mm Max |
Ex d Cable Glands/Plugs NOT Included | Customer needs to supply and use ATEX/IECEx certified Ex db IIC Gb or/and Ex tb IIIC Db IP68 cable gland with sealing compound, in accordance with IEC 60079- 0:2011, IEC 60079-1:2014 and IEC 60079-31:2013 |
Mounting method | Wall mount bracket with swivel joint or base mount |
Electrical | Input Voltage | 100~240VAC 50/60Hz (Standard) / 24VAC (Optional) |
Input voltage Tange | ±10% |
Power | 15W |
Communication | | RS485 |
Protocol | Pelco D (Pelco P only upon request) |
Baud rate | 2400 (other baud rates upon request) |
Environment | Air pressure | 80 – 120Kpa |
Temperature | -400C to +600C with heater (-25°C without heater) |
Humidity | ≤ 95% RH (+250C) |
Weights | Unit/ Ship | 16/ 20 Kg |