LNL-1300e Overview The LNL-1300e is a flexible network-wired Lenel hardware module that interfaces either a single door (with 1 or 2 readers) or a set of I/O points to onGuard® systems version 7.1 or higher. The LNL-1300e allows doors or auxiliary I/O to be conveniently wired to an onGuard system using structured cabling and Ethernet, rather than via dedicated RS-485 wiring. When combined with a compatible Lenel Intelligent System Controller, this allows either a 100% Ethernet solution or a hybrid system to be deployed, depending on the security and IT infrastructure considerations of the installation. The LNL-1300e provides the same Local I/O linking and fallback options as traditional serialconnected modules, but with the convenience and flexibility of network connection. The LNL-1300e can be configured in one of two operating modes. When in the network-connected single door controller mode, the LNL-1300e allows one or two readers to be connected, controlling a single door. Two auxiliary inputs and one auxiliary relay output are also available, in addition to dedicated exit request and door contact inputs and a door lock output relay. And, when in the network-connected I/O module mode, the LNL-1300e allows up to four auxiliary inputs and two auxiliary relay outputs to be configured using Lenel’s onGuard system. Features & Functionality • Supports 10/100 Ethernet communications to Lenel Intelligent System Controllers • Advanced Encryption Standard (AES) 128-bit algorithm for communications • Mounts into a standard triple gang switch box for a compact footprint • Firmware stored in flash memory and background download of firmware updates supported • Custom or standard end-of-line resistors supported Specifications Power input | PoE Class 3 power input 12.95W (44.16 BTU/hour), compliant to IEEE 802.3af, or 12Vdc +/-10% 900 mA (36.83 BTU/hour) maximum power supply Note: for UL installations, POE powered devices shall not be used. Power for these devices must be provided by a UL 294 listed power limited source (12Vdc) | Power Output | Reader port 1:12 VDC @ 150 mA, 6.14 BTU/hour Reader port 2: use AUX power port AUX power port: used to power reader 2 and/or strike, not to exceed 650 mA26.62 BTU/hour Thermally protected | Network Port | 10BaseT/100BaseTX Ethernet, IPv4 addressing, NIST Validated 128 bit AES Encryption | Inputs | Four general purpose, programmable circuit type. In Door Controller mode, two general purpose plus dedicated REX and Door contact inputs | Outputs | Two relays - Form-C, 5 Amp, 28 Vdc. In Door Controller mode, one general purpose plus dedicated strike relay output | Reader Ports | Two TTL reader ports or one 2-wire OSDP reader port capable of supporting two readers Reader Port one: Can be configured for one TTL reader, or for one or two OSDP readers Reader Port Two: one TTL reader Note: Note: if two OSDP readers are used, Reader Port Two is not used | LED | 11 status LED’s. TTL, two wire or one wire bi-color support | Buzzer | Can be controlled by LNL-1300e when one-wire LED mode is selected | Dimensions | 5.5”W x 2.75”L x .96”H (140mm x 70mm x 24mm) without bracket 5.5”W x 3.63”L x 1.33”H (140mm x 92mm x 34mm) with bracket | Temperature | Operating: 32°F to 158°F (0°C to 70°C), For UL installations: -10°C to +49°C (14°F to 120°F) Storage: -67°F to 185°F (-55°C to 85°C) | Humidity | 10 to 95% relative humidity, non-condensing (RHNC), For UL installations: 85+/-5% at 30+/-2°C (86°F) | Approvals | FCC Part 15, Class A, CE Mark, RoHS, WEEE, UL 294, UL294B, CSA-C22.2 No. 205, UL1076, ULC/ORD-C1076 |
|