Features & Functionality • Supports 10/100 Ethernet communications to LenelS2 X-Series Intelligent System Controllers • Advanced Encryption Standard 256-bit encryption supported • Mounts into a standard ANSI/NEMA triple gang switch box for acompact footprint • Firmware stored in flash memory; background download of firmware updates supported • Custom or standard end-of-line resistors supported Features when in network-connected single door controller mode: • OSDP reader port supports four OSDP reader addresses • Paired or single reader support per door • Supports OSDP, including biometric template transfer and Secure Channel encryption • Two outputs; one dedicated for a strike and one general purpose (Form C, 2A @ 30Vdc) per door • Two fixed inputs for door contact and request to exit (REX) per door • Two programmable auxiliary inputs, one for each door Features when in network-connected I/O module mode: • Four general-purpose auxiliary relay outputs (Form C, 2A @ 30Vdc) • Six programmable auxiliary inputs (supervised or unsupervised) Extended Functionality: • Connect supported FIPS-201 readers for embedded authentication (when used with LNL-X4420 and appropriate onGuard software, licenses and third-party hardware) Specifications The interface is for use in low voltage, Class 2 circuits only. | The installation of this device must comply with all local fire and electrical codes. | Primary Power | PoE (12.95 W), compliant to IEEE 802.3af or PoE+ (25 W), compliant to IEEE 802.3at or 12 Vdc ±10%, 1.7 A maximum | Power Output | PoE: VO (TB4-1) and RVO (TB7-4), combined: 12 Vdc @ 0.66 A PoE+ or external 12 Vdc: VO (TB4-1) 12 Vdc @ 1 A max, RVO (TB7-4) 12 Vdc @ 0.5 A max | Communication | Ethernet: 10-BaseT/100Base-TX | Inputs | Six unsupervised / supervised, standard EOL: 1k/1k ohm, 1%, 1/4 watt | Outputs | Four relays: Form-C contacts: 2 A @ 30 Vdc resistive | Reader Interface | Power | 12 Vdc @ 0.5 A max (RVO, TR7-4) | Communications | 2-Wire RS-485, OSDP™ protocol, four device max. | Cable Requirements | External Input Power | 1 twisted pair, 18 AWG (if required) | Communications | Ethernet, CAT-5, minimum | Alarm Input | 1 twisted pair per input, 30 ohms maximum, typically 22 AWG @ 1000 ft. (304.8m) | Relay Outputs | As required for the load | Reader Data and Power* | RS-485/power: 2 twisted pair with shield, 24 AWG, 120 ohm impedance and Power* 4000 ft. (1220m) maximum Or RS-485: 1 twisted pair with shield, 24 AWG, 120 ohm impedance, 4000 ft. (1220m) maximum and Power: 1 pair 18 AWG* *Type of cable(s) and gauge determined by length and voltage/ | Mechanical | Dimensions (W x L x H) | 5.5 x 2.75 x 0.96 in. (140 x 70 x 24 mm) without bracket 5.5 x 3.63 x 1.33 in. (140 x 92 x 34mm) with bracket | Weight | 4.0 oz. (112g) without bracket 5.0 oz. (142g) with bracket | Environmental | Temperature | -55 to 85°C, storage 0 to 70°C, operating | Humidty | 5 to 95% RHNC | Heat Output (BTUs) | at 12 VDC, 8.2 BTU/hr | Approvals | FCC Part 15, CE, RoHS, UL 294, UL 1076, CAN/ULC 60839-11-1:2016, CSA C22.2 No. 205-1983, cUL/ ORD-C1076 |
|