Features & Functionality Controller Functionality • DNS device naming through DHCP extended commands • 6 MB of available on-board, non-volatile flash memory • Battery-backed, non-volatile storage of 50,000 events • Configurable option for Data at Rest encryption • Firmware stored in flash memory, background download of firmware updates supported • Supports up to sixteen badge formats • Biometric template storage support for OSDP™ Biometric and legacy Bioscrypt® readers • Optional Secondary NIC, USB port (2.0) with optional adapter • Enhanced anti-passback capabilities • Up to 32,000 access level permissions • Elevator control support for up to 128 floors • Individual extended held open and strike times • Two dedicated inputs for tamper and power failure status • Advanced Encryption Standard (AES) 256-bit algorithm for communications to Lenel Series 3 reader and I/O modules; AES 128 bit encryption to Lenel Series 2 reader and I/O modules • AES128 or TLS 1.2 (with AES256 support) communication to onGuard • RNDIS support enables USB connection to display controller web configuration pages Reader Interface Functionality • Supports Data 1/Data0, Clock/Data, Supervised and Unsupervised F2F and OSDP-compatible RS-485 readers and keypads • Support for OSDP Biometric template transfer and Secure Channel Encryption • Door contact supervision (open/closed) and REX push-button monitor for each door Specifications The interface is for use in low voltage, Class 2 circuits only. | The installation of this device must comply with all local fire and electrical codes. | Primary Power | 12 to 24 VDC ± 10%, 500 mA maximum (reader current not included) | Power Output | 600 mA maximum (add 600 mA to primary power current) | Primary Host Communication | Ethernet: 10-BaseT/100Base-TX | Secondary Host Communication | USB port (2.0) with optional adapter: pluggable model USB2-OTGE100 | Serial I/O Device | One each: 2-wire RS-485, 2,400 to 115,200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit | Inputs | Eight unsupervised / supervised, standard EOL: 1k/1k ohm, 1% 1/4 watt; two unsupervised inputs dedicated for cabinet tamper and UPS fault monitoring | Outputs | Four relays: Normally open contact (NO): 5 A @ 30 VDC resistive; Normally closed contact (NC): 3 A @ 30 VDC resistive | Reader Interface | Power | 12 VDC ± 10% regulated, 300 mA maximum each reader (input voltage [VIN] must be greater than 20 VDC) or 12 to 24 VDC ± 10% (input voltage passed through), 300 mA maximum each reader | Data Inputs | TTL compatible, F/2F or 2-wire RS-485 | RS-485 Mode | 9,600 to 115,200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit. Maximum cable length: 2,000 ft. (609.6m) | LED Output | TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum | Buzzer Output | Open collector, 12 VDC open circuit maximum, 40 mA sink maximum | Cable Requirements | Power | One twisted pair, 18 to 16 AWG | Ethernet | CAT-5, minimum | TTL Reader | 22 to 16 AWG, depending on length and requirements | Alarm Input | One twisted pair, 30 ohms maximum, typically 22 AWG @ 1,000 ft. (304.8m) | RS-485 I/O Device Port | One twisted pair with drain wire and shield, 120 ohm impedance, 24 AWG, 4,000 ft. (1,219m) maximum | RS-485 Reader Port | One twisted pair with drain wire and shield, 120 ohm impedance, 24 AWG, 2,000 ft. (610m) maximum | Mechanical | Dimensions | 8.0 W x 6.0 L x 1.0 H in. (203.2 x 152.4 x 25mm) | Weight | 9.0 oz. (255g) nominal, board only | Environmental | Temperature | -55° to +85° C, storage 0° to +70° C, operating | Humidity | 5 to 95% RHNC | Heat Output (BTUs) | at 12 VDC, 20.5 BTU/hr at 24 VDC, 22.9 BTU/hr | Approvals | FCC Part 15, CE, RoHS, UL 294, UL 1076, CAN/ULC 60839-11-1:2016, CSA C22.2 No. 205-1983, cUL/ORD-C1076 |
|